  • Number of monitoring channnels:  
     
  • Number of process data channels:

  • Acquisition mode:

  • Frequency band:

  • Sampling rate:

  • Resolution:

  • Recording time:

  • Trigger range:

  • Applicable codes and standards:


  • Max. event frequency:


  • Data storage:

  • Storage requirements:
max.24

max.24

all channels in parallel

1 kHz bis 10 kHz

50 kHz / 100 kHz

15 bit plus prefix

50 ms / 100 ms

1,5 bis 300 g (m/s²)

KTA 3204 and KTA 3201.4, DIN 25 475 part 1,
IEC 988, NRC 1.133, OM 12

5/s up to 10.000 events
(with50 ms recording time)

Memory Card, CD or DVD

approx. 0.5 Mbyte per event with fully expanded system